Table 10-1 Power cord requirements for specic countries and regions (continued)
Country/region Accredited agency Applicable note number
1. The exible cord must be Type HO5VV-F, three-conductor, 0.75 mm² conductor size. Power cord set
ttings (appliance coupler and wall plug) must bear the certication mark of the agency responsible for
evaluation in the country or region where it will be used.
2. The exible cord must be Type SVT/SJT or equivalent, No. 18 AWG, three-conductor. The wall plug must
be a two-pole grounding type with a NEMA 5-15P (15 A, 125 V ac) or NEMA 6-15P (15 A, 250 V ac)
conguration. CSA or C-UL mark. UL le number must be on each element.
3. The appliance coupler, exible cord, and wall plug must bear a T mark and registration number in
accordance with the Japanese Dentori Law. The exible cord must be Type VCTF, three-conductor, 0.75
mm² or 1.25 mm² conductor size. The wall plug must be a two-pole grounding type with a Japanese
Industrial Standard C8303 (7 A, 125 V ac) conguration.
4. The exible cord must be Type RVV, three-conductor, 0.75 mm² conductor size. Power cord set ttings
(appliance coupler and wall plug) must bear the CCC certication mark.
5. The exible cord must be Type H05VV-F three-conductor, 0.75 mm² conductor size. KTL logo and
individual approval number must be on each element. Approval number and logo must be printed on
a
ag label.
6. The exible cord must be Type HVCTF three-conductor, 1.25 mm² conductor size. Power cord set ttings
(appliance coupler, cable, and wall plug) must bear the BSMI certication mark.
7. For 127 V ac, the exible cord must be Type SVT or SJT 3-conductor, 18 AWG, with plug NEMA 5-15P
(15 A, 125 V ac), with UL and CSA or C-UL marks. For 240 V ac, the exible cord must be Type H05VV-F
three-conductor, 0.75 mm² or 1.00 mm² conductor size, with plug BS 1363/A with BSI or ASTA marks.
98 Chapter 10Power cord set requirements