Troubleshooting 3-11
Chassis code 9xxx Console Initialization
errors
a. Check console path and actual configured path.
b. Check console cable and connections.
c. Check core I/O PCA.
d. Replace Core I/O PCA.
e. If the problem persists, call the Response Center.
Chassis code A088 No console control-
ler, unable to boot
a. Check console path and configured path.
b. Check console cable and connections.
c. Replace Core I/O PCA.
d. If the problem persists, call the Response Center.
Chassis code A008 No bootable device
found
a. Attempt to boot from another device.
If boot succeeds, replace the boot device.
If boot fails replace Core I/O PCA.
Chassis code BE00, xxxx,
DEAD (looping)
MPE/iX Monitor Halt
(Halt 0)
a. To determine cause and action to take, refer to Table
3-8 (xxxx is defined in table 3-8).
b. If possible HPMC, refer to troubleshooting HPMC
section.
Chassis code BE07, xxxx,
DEAD (looping)
MPE/iX System
Abort (Halt 7)
a. Perform a Transfer of Control (TOC).
b. Perform a memory dump (refer to taking a memory
dump section).
c. If the problem persists, call the Response Center.
Chassis code
CBFF, xxxx (looping)
Nested HPMC a. Perform a Transfer of Control (TOC).
b. Refer to troubleshooting HPMC section.
Table 3-8. MPE/iX OS Codes (Halt 0)
OS Code Action
0001 to 0099 Take a memory dump and call the response center.
00F1 to 00F3 Take a memory dump. Replace the appropriate CPU card. This may also be an OS bug.
00F4 to 00F7 and 03xx HPMC may have occurred. Refer to troubleshooting HPMC section.
00F8 to 00FB Take a memory dump. Replace the appropriate CPU card. This may also be an OS bug.
Table 3-7. System Hardware Troubleshooting (Continued)
symptom Cause Action