1. In HP Command View EVA, go to the Hardware folder in the Navigation pane and select a disk
enclosure.
The Disk Enclosure Properties window opens.
2. Select the I/O tab.
3. Verify that 0073 displays in the Firmware revision field (for both I/O module A and B). See
Figure 19. If so, the upgrade was successful. If not, resetting the I/O module is recommended.
Figure 19 I/O tab of Disk Enclosure Properties window
.
In a few cases, it has been observed that some fields on the I/O tab of the Disk Enclosure Properties
window appear blank, specifically Hardware revision, Hardware type, and Assembly serial number
(see Figure 20). These blank fields do not affect I/O module operation and do not indicate that the
upgrade was unsuccessful. HP recommends that you wait 20 minutes to see if the situation corrects
itself. If not, you can reset the I/O module to populate these fields (optional).
Upgrading the Enterprise Virtual Array60