210 Chapter 4 Service Tests, Utilities & Calibrations
Tests, Utilities & Calibrations
Scan OMAS Calibration Pattern
1. You will need to re-enter the OMAS Calibration submenu and scroll to “Scan Calibration Pattern”
and press OK.
2. When the following message displays on the front panel, you must select whether you would like to
continue with the calibration by pressing the OK key. Press Back or Cancel to exit the calibration.
3. A message will display advising you that you will need to load the OMAS Calibration Pattern in to
the Printer. Make sure that you rotate the printed pattern 90° clockwise and reload it printed-side
down. Press the OK key to continue.
4. Load the OMAS Calibration Pattern following the instructions on the Front Panel.