370 Chapter 8 Removal & Installation
Removal & Installation
Vacuum Fan
Removal
1. Remove the Right Cover
⇒
See page 319
.
2. Remove the Right Connector Cover
⇒
See page 341.
3. Remove the Primer Assembly
⇒
See page 355.
4. Remove the Primer Valves
⇒
See page 357.
5. Remove the Printhead Maintenance Cartridge
⇒
See
the User’s Guide.
6. Remove the Service Station
⇒
See page 364.
7. Release the Pinchwheel Lever Sensor Cable from the
Vacuum Fan.
8. Disconnect both Vacuum Fan cables (identified 1 and
2) from the Interconnect PCA.
WARNING!: Switch off the printer and remove the power cable.