Continuable and Non-Continuable Error Codes 83
System Error Codes
Check the dryer resistor values, if they are too high, or there is an open circuit, replace the Dryer
module Page 498.
Replace the Heater Control Assembly Page 465 (60 inch).
SE Code: 14.06:00 - One or more heaters are not connected
Problem Description:
There is a communication failure between the Heaters Control Assembly and the Curing Module or Dryer
Assembly.
Corrective Action:
Check all the cables are correctly connected from the Heaters Control assembly to the Curing
module and the Dryer Assembly around the left arc.
Check that none of the cables are damaged, if they are replace them.
Check the cables are connected between the Heaters Control Assembly PCA and the Sausalito
PCA.
SE Code: 14.07:00 - Connection problem with Heaters Control assembly
Problem Description:
I2C Protocol not working. The firmware has detected that there is no communication to/from the Heaters
Control Assembly and the Printmech PCA.
Corrective Action:
Check all the cables are connected between the Heaters Control assembly and the PrintMech
PCA, try disconnecting and reconnecting them.
If there is no light on the 5v LED on the Heater Control PCA, (refer to Page 49) this would
indicate a lack of 5v to the Heaters Control assembly, check the cables from the PrintMech.
Replace the Heaters Control assembly Page 465 (60 inch.).
Replace the PrintMech PCA Page 482.
SE Code: 14.08:00 - No AC voltage in the Dryer Assembly
Problem Description:
The firmware has detected that there is no AC voltage in the Dryer Input connection.
Corrective Action:
Check that the power cables are correctly inserted at the rear of the printer. Check to see if a fuse
has blown on one of the electrical input cables (when the region has a fuse in the power cord).
Check to see if the Residual Current Circuit Breaker (RCCD) has blown, reset it, if it blows again
immediately (or often), this would indicate an error with the Dryer Assembly or the RCCD.
Check the electrical supply from the customer´s site.
Check that the power cables are correctly inserted at the rear of the printer.
Check to see if the Residual Current Circuit Breaker (RCCD) has blown, reset it, if it blows again
immediately (or often), this would indicate an error with the Dryer Assembly or the RCCD.
Check the connections of the cables from the Dryer input connection, RCCD, the filter and the Heater
Control Assembly.