50 Chapter 2 System Error Codes
System Error Codes
• If the System Error continues, replace the Hard Disk Drive ⇒ Page 377.
System Error:
06:10
Problem Description:
Main NVM failure - not detected, read/write failed or readback error.
Corrective Action:
Try the following:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
• If the System Error continues, replace the Hard Disk Drive ⇒ Page 377.
System Error:
07:10
Problem Description:
Aerosol Fan driver burnt.
Corrective Action:
Try the following:
• Replace the Interconnect PCA ⇒ Page 357.
•
If the System Error continues, replace the
Sausalito PCI
PCA
⇒
Page 369.
System Error:
08:11
Problem Description:
Problem with communication between the Front Panel, the Formatter and the HDD.
Corrective Action:
Try the following:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
• Check that the Front Panel cable is not damaged and is correctly connected to the Front Panel and to
the Interconnect PCA.
• Check that the Memory Module is installed correctly.
• Check that the cables between the Interconnect PCA and the Main PCA are not damaged and are
correctly connected.
• Check that the cables between the Hard Disk Drive and the Power Supply Unit and the Main PCA
are not damaged and are correctly connected.
• Check that the cable between the Power Supply Unit and the Main PCA is not damaged and is
correctly connected.
NOTE: Replace one part at a time and check if the error has cleared before replacing
another.