Reset Calibration Flag
Always reset the calibration flag before replacing the Drop Detector, so that the printer will not try to
perform drop detection until the new Drop Detector has been calibrated.
1. In the Service Calibrations submenu, select Drop Detector calibration and press OK.
2. In the Drop Detector Calibration menu, select Reset Calibration Flag and press OK.
3. When the following message appears on the front panel, press OK to continue with the
calibration; press Cancel to exit.
4. The printer resets the calibration flag. Press OK to return to the menu.
5. Turn off the printer and replace the Drop Detector.
6. Turn on the printer and calibrate the Drop Detector.
Drop Detector calibration
1. In the Service Calibrations submenu, select Drop Detector calibration and press OK.