Appendix B
Powering On and Off the System
Shutting Down the System
206
Powering Off the System Using the pe Command
Perform the following steps to power off a cell board for removal.
Step 1. From the Command Menu, enter pe.
Figure B-10 Power Entity Command
Step 2. Enter the number of the cabinet to power off. In this example of Figure B-10, the number is 0.
Step 3. When prompted for the state of the cabinet power, enter off.
Step 4. Now enter ps (Power Status Command) at the CM prompt to view the power status.
Figure B-11 Power Status First Window