Branch circuit breaker specications
4 poles, 32/40 A
Power cable specications
Conguration 3 lines + N + PE
Minimum cross-sectional area 6 mm² or 10 AWG
Terminals Ferrule terminals, except the PE terminal, which uses the M8 ring type
External diameter range 18.0–25.0 mm
Conguration 2: 200–240 V line-to-line three-phase conguration
Printer specications
Number of power wires) 3 lines + PE
Input voltage (line to line) 200–240V (±10%)
Input frequency 50/60 Hz
Power consumption (typical) 9–11 kW
Maximum load current (per phase) 48 A (up to 60 A repetitive peak current)
Branch circuit breaker specications
3 poles, 50/60 A
Power cable specications
Conguration 3 lines + PE
Minimum cross-sectional area 10 mm² or 6 AWG
Terminals Ferrule terminals, except the PE terminal, which uses the M8 ring type
External diameter range 18.0–25.0 mm
Power cables
No power cable is provided with the printer. The cables that you use must meet the minimum specications for
the chosen conguration explained for each conguration, and must follow local laws. The example below is for
conguration 2.
ENWW Printer electrical conguration 19