Table 2-45 Troubleshooting menu (continued)
First level Second level Third level Fourth level Values Description
Diagnostic Tests
(continued)
Paper Path Test
(continued)
Test Duplex Path O*
On
Number of Copies Range: 1–500
Default = 1
Sets the default number
of copies for a copy job.
This default applies when
the Copy or Quick Copy
function is initiated from
the printer Home screen.
The factory default
setting is 1.
Manual Sensor Test Select from a list of
available components.
Reset Sensors
Test the printer sensors
and switches for correct
operation. Each sensor is
displayed on the control-
panel screen, along with
its status. Manually trip
each sensor and watch for
it to change on the
screen. Press the Stop
button to abort the test.
Tray/Bin Manual
Sensor Test
Select from a list of
available components.
Reset Sensors
Test the sensors in the
trays and bins for correct
operation. Each sensor is
displayed on the control-
panel screen, along with
its status. Manually trip
each sensor and watch for
it to change on the
screen. Press the Stop
button to abort the test.
Component Test Select from a list of
available components.
Use this item to exercise
individual parts
independently to isolate
noise, leaking, or other
issues. To start the test,
select one of the
components. The test will
run the number of times
specied by the Repeat
option. The user might be
prompted to remove
parts from the printer
during the test. Press the
Stop button to abort the
test.
Print/Stop Test (M552,
M553)
Specify the length of time
in milliseconds
(0-60,000).
Scanner Tests (M577) Sensors
Fax Test Report
(M577)
Touch Start to process the
Fax Test Report.
Continuous Scan
(M577)
2-sided
ENWW Tools for troubleshooting 259