2. Release one tab (callout 1), and then rotate the top of the cover (callout 2) down to release it.
Figure 2-120 Release the cover
3. Release one tab (callout 1), and then remove the roller (callout 2).
IMPORTANT: Use a damp, lint-free cloth to gently clean the rollers.
NOTE: When handling the rollers or pads, avoid touching the spongy surfaces. Skin oils and
ngerprints on a roller surface can cause print-quality problems.
Reinstallation tip: Reverse the removal steps to install the assembly.
Figure 2-121 Remove the roller
286 Chapter 2 Solve problems ENWW