4. Remove the rubber blade and place the new one in position.
5. Replace the screws. Screw them in with one hand while holding the spacer in place.
Finish off after replacing the rubber blade
1. Push the printhead cleaning material back into place and close the pinchwheel (using the black plastic
knob).
2. Carefully push the printhead cleaning roll carriage back into its working position.
3. Close and lock the door.
Clean the perforated plate
Risk of burns Crush hazard Risk of trapped fingers Hazardous moving part Electric shock hazard
For more safety information, please see
Safety precautions on page 2
The perforated plate is a drilled metallic sheet located in the curing assembly. Through its holes the curing
fans blow hot air onto the substrate.
Prepare to clean the perforated plate
1. Ensure that the printer is not printing.
2. Unload the substrate.
3. Turn off the printer in the correct way for maintenance operations: see
Turn the printer off on page 119.
4. Wait for the curing modules to cool down (approx. 5 min).
5. Remove the spindle.
Pull out the curing assembly
1. Open the front door.
162 Chapter 8 Hardware maintenance ENWW