8
Figure 5-43 Reinstalling the stapler (3 of 3)
Reinstallation tip Make sure that the actuator rod (callout 8) is inserted into the hole in the
stapler and that it moves freely.
Stapler testing – to be performed after the device is fully reassembled
WARNING! Incorrect reinstallation of the stapler can cause the stapler-door switch to operate
incorrectly, resulting in a safety hazard. Test the stapler for correct operation before releasing
the device back to the customer.
Final stapler-test procedure
Test #1: Does the stapler operate correctly when the stapler door is closed?
With the stapler door closed, use the stapler to staple several sheets of paper together. The stapler
should staple the sheets.
Test #2 (safety-switch test): Does the stapler operate when the stapler door is open?
Open the stapler door and attempt to use the stapler to staple several sheets of paper together. When
the stapler and stapler door safety-switch are operating correctly, the open door cuts power to the stapler
and the stapler does not staple the sheets.
ENWW Stapler 121