12 tap test results (REDI sensor values)
Table 1-2 12 tap test report
Callout Report area Item Acceptable values
1 Print Humidity Sensor Data Stable Relative Humidity 0–100 RH
2 Pen TSR Ambient Temperature
Estimate
Pen TSR Ambient Temperature x10
°C
± 10 °C of current ambient
temperature
3 Digital Temperature Sensor
Ambient Temperature
Digital Temperature Sensor
Ambient Temperature x10 °C
± 10 °C of current ambient
temperature
4 Print REDI Sensor Calibration Data
TOF sensor, p value
1
Between 10 and 100
5 Print REDI Sensor Calibration Data
TOF sensor, m value
1
Between 25 and 380
1
“M” is mirror result, “P” is blocked with paper.