Standard Operation Procedure
Document No. : Grizzly disassembly SOP Station:
Operation Name : Ver. : Edit date:
Fixture list (Spec.) Qty
Step:
Notice: Please inform production line leader or master if you found any abnormal..
Issued:Prepared: Zhou.gui-ling
IE department
Safe
Order
Hear
Look
Do
Static
Qual
ity
Fixtur
e
Symbol
Disassembly Finger print
19(1/1)
1. Loosen screw M2.0*1.5 fixed finger print bracket or dummy finger print.
2. Take out bracket and finger print or dummy finger print from unit.
❖ Torque:1.5 ± 0.2 kgf.cm
❖ screw can not be slipped.
Screw driver 1
1.00
Take out finger
print
Loosen screw
Loosen screw
2020/09/15