Removal and replacement procedures 55
a.
Using the guide pin on the processor backplate, position the heatsink.
b. Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c. Finish the installation by completely tightening the screws in the same sequence.
4. Install the processor air baffle.
5. Install the access panel.
6. Do one of the following:
o Slide the server into the rack.
o Install the server into the rack.
7. Connect each power cord to the server.
8. Connect each power cord to the power source.
9. Power up the server.
Processor
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
CAUTION: To prevent possible server overheating, always populate processor socket 2 with a
processor and a heatsink or a processor socket cover and a heatsink blank.
CAUTION: To avoid thermal shutdown, fans must be installed in slots 2 and 5 and a fan blank
must be installed in slot 1 in a dual processor configuration.