Removal and replacement procedures 31
o
If only one hot-plug power supply is installed, power down and remove the power cord from the
server ("Power down the server" on page 24).
o If more than one hot-plug power supply is installed, continue with the next step.
2. Unfasten the cable management solution to access the power supply bays.
3. Disconnect the power cord from the power source.
4. Disconnect the power cord from the power supply.
5. Remove the hot-plug power supply.
WARNING: To reduce the risk of electric shock or damage to the equipment, do not connect
the power cord to the power supply until the power supply is installed.
To replace the component:
1. Slide the hot-plug power supply into the power supply bay.
2. Connect the power cord to the power supply.
3. Install the cable management arm, if removed.
4. Route the power cord through the cable management arm or power cord anchor.
NOTE: If using the power cord anchor, be sure to leave enough slack in the power cord so
that the redundant power supply can be removed without disconnecting the power cord from
the primary power supply.
5. Close the cable management arm.
6. Connect the power cord to the power source.
7. Be sure that the power supply LED is green ("Rear panel LEDs and buttons" on page 68).
8. Be sure that the power supply LED on the SID is green ("HP Systems Insight Display LEDs" on page
72).
Hard drive cage
To remove the component:
1. Power down the server (on page 24).
2. Extend the server from the rack (on page 25).