Diagnostics and Troubleshooting
4-46 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-16: ADU Diagnostic Messages continued
Message Description Recommended Action
Logical
drive X failed
due to cache
error
This logical drive failed due to a
catastrophic cache error.
Replace the array accelerator board and
reconfigure using the Array Configuration
Utility.
Logical
Drive X status
= FAILED
This status could be issued for
several reasons. If this logical drive
is configured for No Fault Tolerance
and one or more drives fail, this
status will occur. If mirroring is
enabled, and any two mirrored
drives fail, this status will occur. If
Data Guarding is enabled, and two
or more drives fail in this unit, this
status will occur. This status may
also occur if another configured
logical drive is in the Wrong Drive
Replaced or Loose Cable Detected
State.
Check for drive failures, wrong drive
replaced, or loose cable messages. If
there was a drive failure, replace the failed
drive(s), then restore the data for this
logical drive from the tape backup.
Otherwise, follow the wrong drive replaced
or loose cable detected procedures.
Logical
Drive X status
= INTERIM
RECOVERY
A physical drive in this logical drive
has failed. The logical drive is
operating in interim recovery mode
and is vulnerable.
Replace the failed drive as soon as
possible.
Logical
Drive X status
= LOOSE
CABLE
DETECTED
A physical drive has a cabling
problem.
Turn the system off and attempt to
reattach the cable onto the drive. If this
does not work, replace the cable.
Logical
Drive X status
= NEEDS
RECOVER
A physical drive in this logical drive
has failed and has now been
replaced. This drive needs to be
rebuilt from the mirror drive or the
parity data.
When starting the system, select the F1 -
rebuild drive option to rebuild the
replaced drive.
Logical
Drive X status
=
OVERHEATE
D
The Intelligent Array Expansion
System temperature is beyond safe
operating levels, and the system
has shut down to avoid damage.
Check the fans and the operating
environment.
Logical
Drive X status
=
OVERHEATI
NG
The Intelligent Array Expansion
System temperature is beyond safe
operating levels.
Check the fans and the operating
environment.
Logical
Drive X status
=
RECOVERIN
G
A physical drive in this logical drive
has failed and has now been
replaced. The replaced drive is
rebuilding from the mirror drive or
the parity data.
Nothing needs to be done. Normal
operations can occur.
continued