Hardware options installation 58
5.
Install the fan module into the fan bay.
6. Install the access panel (on page 23).
7. Slide the server back into the rack.
8. If the fan installation was made to upgrade the server from a nonredundant to a redundant fan mode,
reboot the server.
Installing the hot-plug fan module if the server is installed in a
friction rail system
1. Power down the server (on page 20).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove the server from the rack (on page 22).
4. Remove the access panel (on page 23).
5. Do one of the following: