Hardware options installation 75
— Secondary PCI riser cage
7. Install the PCI riser cage ("Install the PCI riser cages" on page 26).
IMPORTANT: The server does not power up if the PCI riser cage is not seated properly.
8. Connect all necessary internal and external cabling to the expansion board.
For more information on these cabling requirements, see the documentation that ships with the option.
9. Install the access panel (on page 23).
10. Install the server into the rack ("Installing the server into the rack" on page 33).
11. Power up the server (on page 20).
Graphics card power cable option
Connect the graphics card power cable option to support high-power graphics cards. The server can only
support one graphics card installation. Graphics card installation is only supported in the 8-drive cage
models.
Before installing a high-power graphics card in the server, be sure that the power supplies support the
installation of the card. Because of the high power requirements for the card, a 750-W or higher power
supply might be required. For more information, see the HP website
(http://h30099.www3.hp.com/configurator/).
For more information on estimation of power consumption and proper selection of components, see the HP
website (http://www.hp.com/go/hppoweradvisor).
To connect the cable option:
1. Power down the server (on page 20).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 20).
o Remove the server from the rack (on page 22).
4. Remove the access panel (on page 23).
5. Remove the air baffle (on page 24).