Error messages 141
1708 - Slot X Drive Array Controller - Bootstrap NVRAM restored from backup.
System restart required
Audible Beeps: None
Possible Cause: The specified Smart Array controller Bootstrap NVRAM was restored in one of the following
ways:
It was detected as corrupt, and the backup copy was restored.
It was automatically updated because a newer version was available.
Action:
1. Reboot the server.
2. If the problem still exists, update the controller to the latest firmware version.
1711-Slot X Drive Array - RAID ADG logical drive(s) configured but Array
Accelerator size <= 32 MB
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 5 or upgrading the Array
Accelerator module.
Audible Beeps: None
Possible Cause: This configuration is not recommended.
Action: Migrate logical drives to RAID 5 or upgrade to a larger array accelerator module.
1711-Slot X Drive Array - Stripe size too large for RAID 5/6 logical drive(s)
...This configuration is not recommended due to transfer buffer usage. Consider migrating to lower stripe size via Array
Configuration Utility.
Audible Beeps: None
Possible Cause: This configuration is not recommended because of controller memory requirements.
Action: Perform RAID migration to lower stripe size using the Array Configuration Utility (on page 71).
1712-Slot X Drive Array - RAID 5 logical drive(s) configured with 56 Drives, but Array
Accelerator size <= 32 MB...
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 0 or 1, reducing the number of
drives in the array, or upgrading the Array Accelerator module.
Audible Beeps: None
Possible Cause: Upgrade the Array Accelerator module to a larger size.
Action: Migrate logical drives to RAID 0 or 1, reduce the number of drives in the array, or upgrade to a
larger-size array accelerator module.
1713-Slot X Drive Array Controller - Redundant ROM Reprogramming Failure
...Replace the controller if this error persists after restarting system.