HP ProLiant DL388 - Hard Drive Cage Option

HP ProLiant DL388
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware options installation 64
Hard drive cage option
Installation of a SAS expander card or an additional SAS controller option is required to support the hard
drive cage option.
1. Power down the server (on page 24).
2. Extend the server from the rack (on page 24).
3. Remove the access panel (on page 25).
4. Disconnect and remove the optical drive cables ("Optical drive cabling" on page 69), if installed.
5. Using a T-15 Torx screwdriver, remove the two optical drive retaining screws, and then remove the
optical drive cage.
6. Remove the two primary hard drive retaining screws, and then slide the primary hard drive cage
forward.
7. Install the optional hard drive cage.