b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the air baffle .
Removing all high performance heatsinksRemoving all high performance heatsinks
9. Allow all internal system components to cool before continuing.
10. CAUTION:CAUTION:
Heatsink screws must be tightened and loosened in alternating sequence. Do not overtighten the screws as this might
damage the system board or the processor socket.
Use a T-30 Torx screwdriver to loosen one pair of diagonally opposite heatsink screws (callouts 1 and 2), and then loosen the other pair
of heatsink screws (callouts 3 and 4).
11. Set the anti-tilt wires to the unlocked position.