EasyManua.ls Logo

HP Proliant DL580 - Installing the Battery-Backed Write Cache Enabler; Battery-Backed Write Cache Enabler

HP Proliant DL580
289 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing Hardware Options
Table 5-9: Battery-Backed Write Cache Enabler
Item Description
1 Mounting holes
2 Cable connector
Installing the Battery-Backed Write Cache Enabler
To install the BBWCE:
1. Power down the server. Refer to “Powering Down the Server” in this chapter.
2. Extend the server from the rack. Refer to “Extending the Server from the Rack”
in this chapter.
3. Remove the access panels. Refer to “Opening and Removing the Access Panels”
in this chapter.
4. Remove all PCI-X cables and any cards that may be installed. Refer to Chapter 7,
“PCI-X Technology.”
5. Pull up on the two plastic rivets to disengage them from the front fan cage (1).
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide 5-49
HP CONFIDENTIAL
Writer: Karen Hale File Name: f-ch5 Installing Hardware Options.doc
Codename: Dwarf Part Number: 230835-003 Last Saved On: 6/26/03 9:31 AM