Hardware options installation 64
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all PCI slots have either an expansion slot cover or an expansion board installed.
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).
To install the component:
1. Power down the server (on page 15).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 15).
o Remove the server from the rack (on page 18).
4. Remove the access panel (on page 18).
5. Remove the PCI blank.
Retain the blank and screws for future use.
6. Remove the slot cover from the riser cage.