HP Smart Array errors 110
Message Id: 24586
Severity: Informational
Log message: The <drive type> physical drive located in bay <bay number> is now
online. This drive can be found in box <box number> which is connected to port
<port number> of the array controller <controller name / slot information>.
Message Id: 24587
Severity: Warning
Log message: The <drive type> physical drive located in bay <bay number> is in a
SMART trip state that indicates the drive has reached 0 percent usage left.
Indicates that the drive has a SMART wear error and is approaching the maximum
usage limit for writes (wear out). The drive should be replaced as soon as
possible. This drive can be found in box <box number> which is connected to port
<port number> of the array controller <controller name / slot information>.
Message Id: 24588
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature has exceeded the preset limit. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. The array controller may attempt to shut down power
to the attached box and/or spin down the installed disk drive(s).
Message Id: 24589
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature is nearing the preset temperature limit. This sensor is located in
box <box number> which is connected to port <port number> of array controller
<controller name / slot information>. The array controller may enact
precautionary measures to prevent data loss should the temperature reach the
operating limit.
Message Id: 24590
Severity: Informational
Log message: Sensor number <sensor number> has reported that a previously existing
temperature condition has been corrected. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. All of the temperature sensors in the attached box are
now reporting acceptable temperature levels.
Message Id: 24591
Severity: Warning
Log message: Redundant power supply number <power supply number> has reported a
fault. This power supply is located in box <box number> which is connected to
port <port number> of array controller <controller name / slot information>.
Message Id: 24592
Severity: Informational
Log message: Redundant power supply number <power supply number> is no longer sensed
as being in a failed state. Some possible reasons that would cause this state
change to occur include: