EasyManua.ls Logo

HP ProLiant Gen9 - Page 298

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Microsoft Windows Event ID and SNMP traps 298
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaCntlrBoxIoSlot
cpqFcaCntlrStatus
cpqFcaCntlrModel
cpqFcaCntlrSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: “Status is now [cpqFcaCntlrStatus].”
NT Event ID: 1152 (Hex)0x84350480 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Module Status Change.
Log Message: Storage system “%4” fan module at location %5 has a new status of %6.
SNMP Trap: cpqSsEx2FanStatusChange - 8020 in CPQSTSYS.MIB
Symptom: Storage system fan status change. The agent has detected a change in the fan module status of a
storage system. The variable cpqSsFanModuleStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsFanModuleLocation
cpqSsFanModuleStatus
cpqSsFanModuleSerialNumber
cpqSsFanModuleBoardRevision
Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsFanModuleStatus].”
NT Event ID: 1153 (Hex)0x84350481 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply Status Change.
Log Message: Storage system “%4” power supply in bay %5 has a new status of %6.
SNMP Trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB
Symptom: Storage system power supply status change. The agent has detected a change in the power supply
status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status.
User Action: If the power supply status is failed, restore power or replace the failed power supply.

Table of Contents