Microsoft Windows Event ID and SNMP traps 301
cpqHoTrapFlags
cpqTapeLibrarySerialNumber
Supporting SNMP Trap Description: “Tape Library [cpqTapeLibrarySerialNumber] Recovered.”
NT Event ID: 1158 (Hex)0x84350486 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Library Degraded.
Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4 is in a degraded condition.
SNMP Trap: cpqTape3LibraryDegraded - 5012 in CPQSCSI.MIB
Symptom: Tape Library Degraded. The Insight Agent has detected that an autoloader unit is in a degraded
condition.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapeLibrarySerialNumber
Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] is in a degraded
condition.”
NT Event ID: 1159 (Hex)0x84350487 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Library Door Open.
Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4 has a door open, so the unit is not operational.
SNMP Trap: cpqTape3LibraryDoorOpen - 5013 in CPQSCSI.MIB
Symptom: Tape Library Door Open. The Insight Agent has detected that the door on an autoloader is open,
so the unit is not operational.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapeLibrarySerialNumber
Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] door opened.”
NT Event ID: 1160 (Hex)0x84350488 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Library Door Closed.
Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4 has a closed door and is now operational.
SNMP Trap: cpqTape3LibraryDoorClosed - 5014 in CPQSCSI.MIB