Microsoft Windows Event ID and SNMP traps 361
NT Event ID: 1136 (Hex)0x44350470 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: A Temperature Sensor Condition has been set to OK. The system's temperature has returned
to the normal operating range.
SNMP Trap: cpqHe3TemperatureOk - 6042 in CPQHLTH.MIB
Symptom: The temperature status has been set to OK in the specified chassis and location. The server's
temperature has returned to the normal operating range.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeTemperatureChassis
cpqHeTemperatureLocale
Supporting SNMP Trap Description: “Temperature Normal on Chassis [cpqHeTemperatureChassis],
Location [cpqHeTemperatureLocale].”
NT Event ID: 1137 (Hex)0x84350471 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The DC-DC power converter is in a degraded state. Replace the power converter.
SNMP Trap: cpqHe3PowerConverterDegraded - 6043 in CPQHLTH.MIB
Symptom: The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot,
and socket.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP Trap Description: “The Power Converter Degraded on Chassis [cpqHePwrConvChassis],
Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].
NT Event ID: 1138 (Hex)0xc4350472 (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: The DC-DC power converter is in a failed state. Replace the power converter.
SNMP Trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB
Symptom: The DC-DC Power Converter condition has been set to failed for the specified chassis, slot, and