Microsoft Windows Event ID and SNMP traps 375
SNMP Trap: cpqRackPowerShedAutoShutdown - 22021 in CPQRACK.MIB
Symptom: Server shutdown due to power shedding. The server blade was shut down due to a lack of power.
User Action: Check power connections or add power supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The server shutdown due to lack of power blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1164 (Hex)0xc435048c (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Server Power On Prevented
Log Message: Server power on prevented to preserve redundancy.
SNMP Trap: cpqRackServerPowerOnFailedNotRedundant - 22022 in CPQRACK.MIB
Symptom: Server power on prevented to preserve redundancy. There is not enough power to power on the
server blade and maintain redundancy for the other blades in the enclosure.
User Action: Check power connections or add power supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server power on prevented to preserve redundancy in blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”