EasyManua.ls Logo

HP ProLiant Gen9 - Page 381

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Microsoft Windows Event ID and SNMP traps 381
Supporting SNMP Trap Description: “Power subsystem DC power problem in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1174 (Hex)0x84350496 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Facility AC Power Problem
Log Message: The AC facility input power has been exceeded for this power enclosure.
SNMP Trap: cpqRackPowerChassisAcFacilityPowerExceeded - 22032 in CPQRACK.MIB
Symptom: Power subsystem AC facility input power exceeded for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem AC facility input power exceeded in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1175 (Hex)0x84350497 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Unknown Power Consumption
Log Message: There is an unknown power consumer drawing power.
SNMP Trap: cpqRackPowerUnknownPowerConsumption - 22033 in CPQRACK.MIB
Symptom: Unknown power consumption. There is an unknown power consumer drawing power.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum

Table of Contents