Microsoft Windows Event ID and SNMP traps 396
SNMP Trap: cpqNicRedundancyReduced - 18004 in CPQNIC.MIB
Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the Failed
condition, but at least one physical adapter remains in the OK condition. This can be caused by loss of link
due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch
failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the
adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: “Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1290 (Hex)0x4435050A (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Connectivity has been restored for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityRestored - 18011 in CPQNIC.MIB
Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the
physical adapter in a single adapter configuration returns to the OK condition or at least one physical
adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a
faulty cable or re-attaching a cable that was unplugged.
User Action: None required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP Trap Description: “Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1291 (Hex)0xc435050B (cpqnimsg.dll)