HP ProLiant server errors 81
1763-Slot X Drive Array - Cache module is detached; please reattach.
Audible Beeps: None
Possible Cause: Cache module is loose, missing, or defective.
Action:
1. Reseat cache module.
2. If the problem persists, replace the cache module.
1763-Slot X Drive Array - Cache daughtercard critical error; please replace...
...(Controller is disabled until this problem is resolved)
Audible Beeps: None
Possible Cause: Cache module is loose, missing, or defective.
Action: Replace the cache module.
1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...
(followed by one of the following:)
...Expansion will resume when Cache Module has been reattached.
* Expansion will resume when Cache Module has been replaced.
* Expansion will resume when Cache Module RAM allocation is successful.
* Expansion will resume when Battery Pack/Super-Cap reaches full charge.
* Expansion will resume when Automatic Data Recovery has been Completed.
* Expansion will resume when Battery Pack/Super-Cap is connected.
Audible Beeps: None
Possible Cause: The capacity expansion process has been temporarily disabled.
Action: Follow the action that is displayed onscreen to resume the capacity expansion process.
1766- Slot X Drive Array...
...requires System ROM Upgrade.
Action: Run the Systems ROMPaq Utility.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps: None
Possible Cause: Power was lost while a logical expansion operation was performed. A controller reset or
power cycle occurs while array expansion is in progress.
Action: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled due to Failure During Expansion...
(possibly followed by one of the following additional details:)
...* Cache Module Removed or Failed; Expansion Progress Data Lost.
* Expansion Progress Data Could Not Be Read From Cache Module.
* Expansion Aborted due to Unrecoverable Drive Errors.
* Expansion Aborted due to Cache Module Errors.
Select "F1" to continue with logical drives disabled