Removal and replacement procedures 32
4-bay LFF hot-plug drive cage
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To remove the component:
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Place the server on its side.
4. Remove the access panel (on page 25).
5. Remove the front bezel (on page 26).
6. Remove all drives ("Hot-plug drive" on page 31).
7. Remove all drive blanks ("Hot-plug drive blanks" on page 30).
8. If installed, remove the PCI air baffle (on page 27).
9. Remove the system air baffle (on page 28).
10. Disconnect the Mini-SAS cable and the power cable from the drive backplane.
11. Disconnect the hard drive power good cable from the system board. Hard drive power good cable is
attached to the drive cage by default.
12. Remove the LFF hot-plug drive cage:
o Box 1