System Unit
System UnitSystem Unit
System Unit
Tower Dimensions
Tower DimensionsTower Dimensions
Tower Dimensions
(H x W x D)
(with feet/bezel)
18.19 x 8.58 x 29.13 in (46.2 x 21.8 x 74.0 cm)
Rack Dimensions
Rack DimensionsRack Dimensions
Rack Dimensions
(H x W x D)
(with feet/bezel)
8.58 x 19.0 x 28.83 in. (21.8 x 48.26 x 73.22cm)
Tower Weight
Tower WeightTower Weight
Tower Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
114.84 lb (52.09 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
70.33 lb (31.9 kg)
Rack Weight
Rack WeightRack Weight
Rack Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
110.36 lb (50.06 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
60.91 lb (27.63 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
852 W
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at
240 VAC)
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
460(750) W (at 100 VAC),
460(750) W (at 200 VAC)
Maximum Peak Power
460(750) W (at 100 VAC),
460(750) W (at 200 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).