Cable Management
117
Some cables may have a bend-radius issue at the connection point. In that case you can use the outside of the
cable guide to secure the cable for strain relief.
The pictures in this section show a single rp7400 SPU with cables. For a cabinet with multiple SPUs or an
SPU with peripheral component bays installed, you would want to cable from the bottom up. Be sure to leave
an adequate service loop in the cables so the SPU can be extended out the front or back of the cabinet. Some
cables may have to be loosened or re-positioned to access and SPU in the middle positions of the cabinet.
CAUTION Always be aware of cable interference while moving an SPU. Cable or connector damage could
occur if this precaution is not followed.
Ultra 2 SCSI
Cable connection
Ultra 2 SCSI
Cable with plastic