Screen message Probable cause Recommended action
1998—Master Boot Record
has been lost
The previously saved copy of the MBR
has been corrupted.
Run Computer Setup and save the MBR of the current
bootable disk.
1998—Master Boot Record
has been changed
The current MBR does not match the
previously saved copy of the MBR.
Use extreme caution. The MBR might have been
updated due to normal disk maintenance activities (disk
manager, fdisk, or format). Replacing the previously
saved MBR in such situations can cause data loss. If
certain that the MBR change is unintentional and
undesired (for example, due to a virus), run Computer
Setup and restore the previously saved MBR copy.
Otherwise, run Computer Setup and either disable
MBR security or save the MBR of the current bootable
disk.
Invalid Electronic Serial
Number
Electronic serial number has become
corrupted.
Run Computer Setup. If Setup already has data in the
field or will not allow the serial number to be entered,
download from
http://www.hp.com and run the utility
SP5572.EXE (SNZERO.EXE).
Run Computer Setup and try to enter serial number
under Security, System ID, and save the changes.
ECC Multiple Bit Error
Detected in Memory Module
Chipset has detected more than one
bad bit in a 64-bit quadword of the
memory array.
Replace the memory module.
Parity Check 2 Parity RAM failure. Run Computer Setup and Diagnostic utilities.
Table 5-18 POST error messages (continued)