Resetting the power supply
If an overload triggers the power supply overload protection, all power is immediately disconnected. To
reset the power supply unit:
1. Disconnect the power cord.
2. Determine what caused the overload and fix the problem.
3. Reconnect the power cord and reboot the workstation.
Environmental specifications
This section describes environmental specifications of your workstation.
Temperature
Operating: 5 to 35°C (40 to 95°F)
Non-operating: -40 to 60°C (-40 to 140°F)
NOTE: Derate by one degree C (1.4 degrees F) for every 305m (1,000 ft.)
altitude over 1,524m (5,000 ft.).
Humidity
Operating: 8 to 85% RH, non-condensing
Non-operating: 8 to 90% RH, non-condensing
Altitude
Operating: 0 to 3,048m (10,000 ft.)
Non-operating: 0 to 9,144m (30,000 ft.)
Shock
Operating: ½-sine: 40g, 2-3ms
Non-operating:
●
½-sine: 160 cm/s, 2-3ms (~100g)
●
square: 422 cm/s, 20g
NOTE: Values represent individual shock events and do not indicate repetitive
shock events.
Vibration
Operating random: 0.5g (rms), 5-300 Hz
Non-operating random: 2.0g (rms), 10-500 Hz
NOTE: Values do not indicate continuous vibration.
PCI card slot power specification
Table 1-17 PCI and PCI Express slot power specifications
Slot Slot type Slot power
(maximum)
1 PCI Express x16 graphics 130 W**
2 PCI Express x8 (4) 25 W*
3 PCI Express x16 (4) 25 W*
4 PCI Express x8 (4) 25 W*
ENWW Product specifications 13