11. Power up the server.
12. If removed, install the front bezel.
Liquid cooling heatsink replacementLiquid cooling heatsink replacement
SubtopicsSubtopics
Removing the liquid cooling heatsinkRemoving the liquid cooling heatsink
Installing the liquid cooling heatsinkInstalling the liquid cooling heatsink
Removing the liquid cooling heatsinkRemoving the liquid cooling heatsink
PrerequisitesPrerequisites
If the reason for replacing the liquid cooling heatsink is due to the coolant leak, first perform the Appendix I: Server coolant spill
response procedure.
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
T-20 Torx screwdriver
Alcohol wipe
About this taskAbout this task
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to
cool before touching them.
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.