If the system power LED is off, verify the following conditions:
Facility power is present.
The power supply is installed and is working correctly.
The power cord is attached and is connected to a power source.
The front I/O cable is connected.
If all LEDs described in this table flash simultaneously, a power fault has occurred. For more information,
see "Power fault LEDs".
SFF drive model
Item Description Status
1 Power On/Standby button and
system power LED
Solid green = System on
Flashing green (1 flash per second) = Performing
power on sequence
Solid amber = System in standby
Off = No power present
1
2 Health LED
Solid green = Normal
Flashing green (1 flash per second) = iLO is
rebooting
Flashing amber = System degraded
2
Flashing red (1 flash per second) = System critical
2
Table Continued