3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel.
8. If the server is in the rear 4 LFF drive configuration, remove the rear 4 LFF drive cage .
9. Remove the primary riser cage.
10. Unplug the USB device from the USB port.
ResultsResults
To replace the component, reverse the removal procedure.
Removing the Removing the boot deviceboot device security cover from the NS204i-u + secondary low-profile riser security cover from the NS204i-u + secondary low-profile riser
cagecage
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.
HPE ProLiant DL345 Gen11 Server Service and Maintenance Guide 179