System maintenance switch descriptionsSystem maintenance switch descriptions
PositionPosition DefaultDefault FunctionFunction
S1 Off Off = iLO security is enabled.
On = iLO security is disabled.
S2 Off Reserved
S3 Off Reserved
S4 Off Reserved
S5 Off Off = Power-on password is enabled.
On = Power-on password is disabled.
S6 Off Off = No function
On = Restore default manufacturing settings
S7 Off Reserved
S8 Reserved
S9 Reserved
S10 Reserved
S11 Reserved
S12 Reserved
To access the redundant ROM, set S1, S5, and S6 to On.
When the system maintenance switch position 6 is set to the On position, the system is prepared to restore all configuration settings
to their manufacturing defaults.
When the system maintenance switch position 6 is set to the On position and Secure Boot is enabled, some configurations cannot be
restored.
For more information, see Secure Boot.