Alcohol wipe
1/4-inch flathead screwdriver
Procedure
1. Observe the following alerts.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor configurations
must contain processors with the same part number.
CAUTION: If installing a processor with a faster speed, update the system ROM before installing the processor.
To download firmware and view installation instructions, see the Hewlett Packard Enterprise Support Center
website.
CAUTION: THE CONTACTS ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the socket or
processor, do not touch the contacts.
2. Power down the server.
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
5.
Remove the access panel.
6.
Do one of the following:
Remove the air bale.
If installed, remove the 4LFF midplane drive cage.
7.
Remove the processor heatsink assembly:
a. Allow the heatsink to cool.
b. Loosen the heatsink nuts in the order specified by the label on the heatsink.
Hardware options installation
146