Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power supplies, and internal system
components to cool before touching them.
CAUTION: Do not operate the chassis for long periods with the access panel open or removed. Operating the chassis in
this manner results in improper airflow and improper cooling that can lead to thermal damage.
Procedure
1.
Power down the server.
2.
Extend the server from the rack.
3.
Open or unlock the locking latch, slide the access panel to the rear of the chassis, and remove the access panel.
Install the access panel
Procedure
1. Place the access panel on top of the server with the latch open.
Allow the panel to extend past the rear of the server approximately 125 cm (05 in).
2. Push down on the latch.
The access panel slides to a closed position.
3. Tighten the security screw on the latch, if needed.
Operations
51