EasyManua.ls Logo

HPE ProLiant DX360 Gen10 - Page 12

HPE ProLiant DX360 Gen10
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description Status
Processor LEDs
O = Normal
Amber = Failed processor
DIMM LEDs
O = Normal
Amber = Failed DIMM or configuration issue
Fan LEDs
O = Normal
Amber = Failed fan or missing fan
NIC LEDs
1
O = No link to network
Solid green = Network link
Flashing green = Network link with activity
If power is o, the front panel LED is not active. For status,
see Rear panel LEDs on page 15.
Power supply LEDs
O = Normal
Solid amber = Power subsystem degraded, power supply
failure, or input power lost.
PCI riser LED
O = Normal
Amber = Incorrectly installed PCI riser cage
Over temp LED
O = Normal
Amber = High system temperature detected
Amp Status LED
O = AMP modes disabled
Solid green = AMP mode enabled
Solid amber = Failover
Flashing amber = Invalid configuration
Power cap LED
O = System is in standby, or no cap is set.
Solid green = Power cap applied
1
For Networking Choice (NC) server models, the embedded NIC ports are not equipped on the server. Therefore, the NIC LEDs on the
Systems Insight Display will flash based on the FlexibleLOM network port activity. In the case of a dual-port FlexibleLOM, only NIC LED
1 and 2 will illuminate to correspond with the activity of the respective network ports.
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. For
more information on the combination of these LEDs, see Systems Insight Display combined LED descriptions on page
13).
12 Component identification

Table of Contents

Related product manuals