Prerequisites
NVMe drives are supported in the 8SFF and 10 SFF server configurations.
Before installing this option, be sure you have the following:
The components included with the hardware option kit
Procedure
1. Observe the following alert:
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
2. Remove the drive blank, if installed.
3.
Press the Do Not Remove button to open the release handle.
4.
Install the drives.
5. Install an SFF drive blank in any unused drive bays.
Hardware options installation 63