Event Title: External Tape Drive Status Change.
Log Message: The tape drive at location “%4”, has a new status of %7.
SNMP Trap: cpqExtTapeDriveStatusChange - 16023 in CPQFCA.MIB
Symptom: External Tape Drive Status Change. This trap indicates that the agent has detected a change in the
status of an External Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status.
User Action: If the tape is failed or is offline, check the tape and all connections.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
cpqFcTapeDriveStatus
Supporting SNMP Trap Description: “Status is now [cpqFcTapeDriveStatus] for a tape drive.”
NT Event ID: 1194 (Hex)0x843504aa (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Tape Drive Cleaning Required.
Log Message: The tape drive at location “%4” requires cleaning.
SNMP Trap: cpqExtTapeDriveCleaningRequired - 16024 in CPQFCA.MIB
Symptom: External Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to
have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
HPE Insight Management Agents for Servers for Windows 371