Configure the Standard Boot Order (IPL) in UEFI System Utilities if changes are required. For more
information, see the UEFI System Utilities user guide for your product on the Hewlett Packard Enterprise
website.
292-Invalid HP Software RAID Configuration
Symptom
292-Invalid HP Software RAID Configuration. HP B140i SW RAID Mode is NOT supported when the Boot
Mode is configured for Legacy BIOS Mode.
Cause
The is configured for Legacy BIOS Mode.
Action
Configure the Boot Mode to UEFI Mode if using SW RAID.
For more information, see the UEFI System Utilities user guide for your product on the Hewlett Packard
Enterprise website.
293-A critical error occurred resulting in a reboot of the system
Symptom
293-A critical error occurred resulting in a reboot of the system. The source of the error could not be
identified. Action: Check hardware and software for issues. Contact HP service if the issue persists.
Cause
A hardware or software issue exists.
Action
1. Check the hardware and software for issues.
For more information, see "POST issues flowchart" in the HPE ProLiant Gen9 Troubleshooting Guide,
Volume I on the Hewlett Packard Enterprise website.
2. If the issue persists, contact Hewlett Packard Enterprise support.
For more information, see "Accessing Hewlett Packard Enterprise support."
294-Memory Board X Training Failure
Symptom
294-Memory Board X Training Failure. DIMMs on this Memory Board are not available to the operating
system. Action: Reseat the Memory Board. If the issue persists, contact HP Support.
Cause
The memory board is not installed correctly.
Action
1. Reseat the memory board.
292-Invalid HP Software RAID Configuration 67