375-NVDIMM Error – Processor X, DIMM Y
Symptom
375-NVDIMM Error – Processor X, DIMM Y. NVDIMM has received a memory initialization or uncorrectable
error. NVDIMM has been disabled. Action: Sanitize the NVDIMM. If problem persists, replace the NVDIMM.
Cause
The has NVDIMM-N Memory Interleaving disabled and one of the following occurred:
• The NVDIMM experienced an uncorrectable error and caused the to reboot.
• The could not initialize the NVDIMM during POST.
Action
1. Reseat the NVDIMMs and all DIMMs in the .
2. Sanitize the NVDIMM.
3. If the error persists, replace the NVDIMM.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise
website. For removal and replacement procedures, see the maintenance and service guide on the
Hewlett Packard Enterprise website.
376-NVDIMM Error – Processor X, DIMM Y
Symptom
376-NVDIMM Error – Processor X, DIMM Y. NVDIMM set for interleaving disabled but system configured for
interleaving enabled. All NVDIMMs on Processor X are disabled. Action: Sanitize all NVDIMMs on Processor
X.
Solution 1
Cause
The NVDIMM was previously being used in a with NVDIMM-N Memory Interleaving disabled, but this is
configured for NVDIMM-N Memory Interleaving enabled.
Action
Disable NVDIMM-N Memory Interleaving and reboot the . Data on the NVDIMM will be available after
rebooting.
Solution 2
Action
Sanitize all NVDIMMs on Processor X. The data on the NVDIMM will not be available after sanitization.
96 375-NVDIMM Error – Processor X, DIMM Y